How to Install CUSHOTRAC® Clamp[ON]™ Pads

Step 1.

Completely remove both clamps from the pad. Lay the pad onto the steel shoe ensuring that the coupling nuts sit down in the valleys of the triple bar grouser shoe.

Step 2.

Attach the removed clips back onto the pad by hand tightening.

Step 3.

Ensure that the CUSHOTRAC® Clamp[On]™ pad is centered horizontally onto the steel shoe. There should be an even gap on both sides between the pad and the clamp. Steel to steel contact between the clips and the steel grouser shoe is required.

Step 4.

Using a torque wrench, alternate tightening each bolt to 25-35ft lbs to ensure pad stays centered on the grouser shoe.